Case study
Oil-Water Separator Engineering for a Guyana Gold Mine
An above-ground separator design for wash-bay and maintenance-pit requirements.

A Guyana-based gold mining venture needed to manage oily water from a wash bay and a maintenance pit. The wash-bay baseline was approximately 60 gallons per minute (GPM), with allowance for gravity-fed solids. Separately, the maintenance requirement called for 200 GPM from a 150 m³ pit, with a target of draining it in approximately three hours.
Ecologix developed an above-ground oil-water separator design and an auxiliary pump package for the stated requirements. The available record documents design and approval; it does not establish installation or measured field performance.
Application Snapshot
| Application | Wash-bay and maintenance-pit oily water at a gold mining venture in Guyana |
|---|---|
| Wash-bay baseline | Approximately 60 GPM, with allowance for gravity-fed solids |
| Maintenance pit | 150 m³, with a 200 GPM requirement and approximately three-hour drain-time target |
| Layout | Above-ground separator requested for site flexibility |
| Wash water | High-pressure, ambient-temperature water with biodegradable degreasers, as reported by the client |
The three-hour drain time was a client target, not a measured result or guarantee. At 200 US GPM, continuously pumping 150 m³ would nominally take about 3 hours and 18 minutes, before allowing for operating conditions.
Requirements and Design Evolution
High-pressure washing and the use of degreasers made the condition of the oil relevant to separation. Gravity separation depends on oil droplets being able to rise; emulsified oil can remain suspended and may require additional treatment. The reported use of biodegradable degreasers does not by itself establish that the oil would remain non-emulsified.
In October 2025, the early discussion included an underground HQB-1048 option with a 1,000-gallon tank and 100 GPM capacity. After the formal request for proposal in November, Ecologix provided above- and below-ground layouts in December and sought clarification of the operating flows. The client supplied data sheets and clarified the wash-bay and maintenance-pit requirements in January 2026.
By April 2026, Ecologix had been named a shortlisted finalist and issued a revised quotation reflecting the updated scope. The executive summary describes the above-ground design as approved; the available chronology does not independently confirm a final award or completed installation.
Specified Above-Ground Separator
The specified AG-5CS-HP above-ground oil-water separator has a design flow range of 1-200 GPM. Its parallel corrugated plate coalescer provides surfaces where non-emulsified oil droplets can combine and rise under calm, laminar-flow conditions.
The source specifies 100% removal of non-emulsified oil droplets at least 30 µm in diameter under laminar flow. This is a design specification, not a demonstrated field result or a claim about emulsified oil.
| Specification | Specified value |
|---|---|
| Tank construction | ¼-inch ASTM A36 carbon steel |
| Internal coating | Tnemec 61, 10-12 mils minimum dry film thickness |
| External coating | Polyamide epoxy, 6 mils minimum dry film thickness |
| Total separator volume | 1,942 gallons |
| Effluent tank volume | 323 gallons |
| Sludge hopper capacity | 75 gallons |

Specified Pump Duties
The quoted pump duties are listed separately from the overall wash-bay and maintenance-pit requirements. The source identifies a 60 GPM wash-bay baseline and, separately, a 200 GPM pump named for wash-bay circulation.
| Quoted duty | Specified equipment |
|---|---|
| Wash-bay circulation | 3-inch bolted Wilden air-operated double-diaphragm (AODD) pump, 200 GPM over a 25 m pipe run, aluminum wetted body and Buna elastomers |
| Truck-shop circulation | 1½-inch bolted Wilden AODD pump, 60 GPM over a 75 m pipe run |
| Wash-bay sludge | 2 HP lobe pump with pressure transducer and liquid-level float kits |

Project Status and Engineering Takeaways
The documented milestone is an approved design and a revised quotation following selection as a shortlisted finalist. Manufacture, shipment, installation, commissioning, compliance and field performance are not independently established by the supplied record.
This application illustrates why oil-water separator selection needs to account for instantaneous flow, solids, oil condition and the intended layout alongside total water volume.
Planning treatment for oily wash water?
Share your flow rates, solids loading, oil condition and site requirements with the Ecologix team.